Conductor
|
Material
|
CCA (Copper content 22%–31%)
|
Diameter
|
0.57 mm ± 0.01 mm (0.0224"±0.0004")
|
Wire Gauge
|
23AWG
|
Insulation
|
Material
|
HDPE
|
Thickness
|
0.21 mm (0.0083")
|
Diameter
|
1.02 mm±0.1 mm (0.0402"±0.004")
|
Color
|
Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
|
Separator
|
Material
|
PE
|
Specification
|
Translucent 4.5 mm × 0.4 mm (0.1772"±0.0157")
|
Rip Cord
|
Material
|
Polyester
|
Specification
|
500D
|
Sheath
|
Material
|
PVC
|
Min. Average Thickness
|
0.5 mm (0.0197")
|
Diameter
|
6.5 mm±0.3 mm (0.2559"±0.0118")
|
Color
|
Orange
|
Electrical
|
Max. DC Resistance of a Single Conductor
|
11.5 Ω/100 m
|
Min. Insulation Resistance
|
5000MΩ·km
|
Max. DC Resistance Unbalance
|
2% (pair intra), 4% (pairs inter)
|
Dielectric Strength
|
No breakdown with 1kV DC for 1 min
|
Transmission
|
Characteristic Impedance
|
100 Ω ± 15 Ω
|
Near End Cross Talk
|
≥39.30 dB/100 m @250 MHz
|
Max. Attenuation
|
34.8 dB/100 m @250 MHz
|
Return Loss
|
≥17.3 dB/100 m @250 MHz
|
Mechanical
|
Tensile Strength
|
Sheath≥13.5 MPa, insulation≥16 MPa
|
Elongation at Break
|
Sheath≥150%, insulation≥300%
|
Installation Bending Radius
|
>8 times of outer cable diameter
|
Conductor Elongation at Break
|
≥10%
|
Environmental
|
Shrinkage of Insulation
|
≤5%
|
Color Migration Resistance of Insulation
|
No migration
|
Sheath Tensile Strength and Elongation at Break after Aging
|
≥12.5 MPa, ≥100%
|
Low Temperature Bending Test
|
No cracking after the test
|
Heat Shock Test
|
No cracking after the test
|
Operation Temperature
|
–20°C to +60°C (–4°F to 140°F)
|
Installation Temperature
|
0°C to +50°C (32°F to 122°F)
|
Storage Temperature and Humidity
|
–10°C to +40°C (14°F to 104°F), <60% (RH)
|
Security
|
Vertical Fire Propagation Test
|
Comply with IEC 60332-1-2
|
Packaging
|
Cable Length
|
100.0 m (328.08 ft)±1 m (3.28 ft)
|
Inner Carton Dimensions
|
286 mm × 119 mm × 289 mm
(11.26" × 4.69" × 11.38")(L × W × H)
|
Net Weight
|
3.2 kg ±0.3 kg (7.05 lb±0.66 lb)
|
Gross Weight
|
3.5 kg ±0.3 kg (7.72 lb±0.66 lb)
|
Packaging Dimensions
|
595 mm × 310 mm × 270 mm
(23.43" × 12.20" × 10.62") (L × W × H)
|
Packaging Method
|
100 m/carton, 4 inner cartons in one package
|
Compliance
|
Executive Standards
|
Q/DXJ 067-2019
|
Certification
|
Certification
|
CPR Eca
|